The following tables indicate the required PTEC levels for the 5.0 Specification. Table 3 below lists PTEC requirements for Version 5.0, while Table 4 gives weightings for each operational mode. PTEC will be determined using the formula below:

P TEC = 0.35 · P off + 0.10 · P sleep + 0.55 · P idle

where all Px are power values in watts.

  1. Table 3:PTEC Requirement - Workstations
  2. Table 4:Operational Mode Weighting - Workstations